Transformer Calculator 電腦版
Yuriy Bodnar
用GameLoop模拟器在電腦上玩Transformer Calculator
Transformer Calculator 電腦版
來自發行商 Yuriy Bodnar 的 Transformer Calculator 能夠在安卓系統上運行。
現在,您可以在電腦上使用 GameLoop 模擬器流暢地玩 Transformer Calculator。
在 GameLoop 遊戲庫或搜索結果中下載。 不需要再暢玩遊戲時盯著電池電量或被令人懊惱的來電打斷。
只需在電腦大屏幕上免費下載暢玩Transformer Calculator 電腦版!
Transformer Calculator 簡介
The application is designed to calculate the cost of power and energy losses in power transformers and autotransformers. It is designed to use the data of the following types of transformers:
a two-winding transformer - voltage transformer having a secondary winding voltage;
three-winding transformers - voltage transformer having two secondary windings: primary and secondary.
Parameters for input:
n - Number of parallel transformers (u.)
Snom - Rated power transformer (kVA)
Smax - Transformer load at maximum capacity (kVA)
Shv - Estimated capacity on the side of higher voltage (HV) transformer (kVA)
Smv - Estimated capacity on the medium voltage (MV) transformer (kVA)
Slv - Estimated capacity on the side of low voltage (LV) transformer (kVA)
ΔPnl - No-load losses of the transformer (kW)
ΔPsc - Loss of the transformer short circuit (kW)
Psc(h-m) - Loss of short-circuit of the high-voltage to the mean (kW)
Psc(h-l) - Loss of short-circuit from the highest to the lowest voltage (kW)
Psc(m-l) - Loss of short-circuiting of the medium voltage to the lowest (kW)
Inl - The value of load current of the transformer (%)
Usc - Short-circuit voltage of the transformer (%)
Usc(h-m) - Short-circuit voltage from a higher voltage to the mean (%)
Usc(h-l) - Short-circuit voltage from a higher to a lower voltage (%)
Usc(m-l) - Short-circuit voltage of the medium voltage to the lowest (%)
Tmax - The time value of the maximum load of the transformer (h.)
Tmax(hv) - The time value of the maximum load on the HV side of the transformer (h.)
Tmax(mv) - The time value of the maximum load on the MV side of the transformer (h.)
Tmax(lv) - The time value of the maximum load on the LV side of the transformer (h.)
Ty - Number of hours of the transformer for the year (h.)
C¤ - The average tariff for active power (¤/kWh.)
Parameters obtained after calculations:
Kl - The load factor of the transformer (rel.u.)
ΔPt - Total losses of active power transformer (kW)
ΔQt - Total losses of reactive power transformer (kvar)
ΔSt - Full power losses in the transformer (kVA)
t - The time of maximum losses (h.)
t(hv) - The time of maximum losses on the HV side (h.)
t(mv) - The time of maximum losses on the MV side (h.)
t(lv) - The time of maximum losses on the LV side (h.)
ΔWat - Active energy losses in the transformer during the year (kWh.)
ΔWrt - Reactive power losses in the transformer for the year (kvarh.)
ΔWt - The total energy loss in the transformer (kVAh.)
C - The annual cost of energy loss (¤ per year)
標籤
工具訊息
開發商
Yuriy Bodnar
最新版本
1.05
更新時間
2023-10-22
類別
工具
同時可用
Google Play
更多
如何在電腦上用 GameLoop 玩 Transformer Calculator
1. 從官網下載GameLoop,然後運行exe文件安裝GameLoop
2. 打開GameLoop,搜索“Transformer Calculator”,在搜索結果中找到Transformer Calculator,點擊“安裝”
3. 享受在 GameLoop 上玩 Transformer Calculator 的樂趣
Minimum requirements
OS
Windows 8.1 64-bit or Windows 10 64-bit
GPU
GTX 1050
CPU
i3-8300
Memory
8GB RAM
Storage
1GB available space
Recommended requirements
OS
Windows 8.1 64-bit or Windows 10 64-bit
GPU
GTX 1050
CPU
i3-9320
Memory
16GB RAM
Storage
1GB available space